X-RAY DIFFRACTION
Welcome to UCLA's J.D. McCullough X-ray Facility
1416 Molecular Sciences Building
Services
Single-Crystal XRD:
Full service single-crystal X-ray diffraction (Mo or Cu Kα radiation)
Single-crystal X-ray data collection
Single-crystal X-ray unit cell determination
Absolute configuration determination (not possible in all cases)
Variable temperature studies (100K – 300K)
Powder XRD:
Powder X-ray data collection
Powder X-ray phase analysis
Note: Powder XRD services are limited to 5 samples. If you have more, we will be happy to train you to run your own samples.
All of the above services have nominal fee. Please consult with Tyler Kerr for charges.
Training
Single-Crystal XRD:
Training in single-crystal X-ray diffraction is available to all who meet the following criteria:
Interest in learning to collect, refine, and/or publish SC-XRD data
Has (or expects to have) many single crystal samples
We offer training that will cater to your needs. If a user desires a full-service XRD dataset and report, if the user is completely independent, or anywhere in between, we are happy to work with you.
Powder XRD:
Standard PXRD training is available to all who need it. Please see our Access & Training page for more information.
Sample Submission
For users inside UCLA, please contact Tyler Kerr directly.
For users outside of UCLA desiring single-crystal analysis, submit your sample and a fully completed sample submission form (copies are also available in the lab) to
Dr. Tyler Kerr
1412 Molecular Science Building
Dept. of Chemistry & Biochemistry
University of California, Los Angeles
Los Angeles, CA 90095-1569
Your sample will be analyzed on a first come first serve basis. Normal turn around time is 2-3 days. For powder samples no sample submission form is required. Outside users should mail properly sealed samples to:
Instrumentation
Panalytical X'Pert Pro X-ray Powder Diffractometer
Installed in 2004
Bragg-Brentano and Parallel Beam Optics
Incident and Diffracted Beam Mirrors
Computer Controlled Slits
X’celerator RTMS Scanning Detector
Sealed Proportional Detector
High Temperature Stage up to 1000°C
Bruker DUO ApexII CCD Single-Crystal X-ray Diffractometer
Installed in 2013
Quazar multilayer Microfocus Cu
Triumph Monochromator Mo-X-ray source
Low temperature device (100K – 300K)
APEX2 software suite
Bruker D8 Discover Powder X-ray Diffractometer
Installed in 2006
Push Plug Gobel Mirror
9-Position Sample Stage
Vantac Detector for Fast Simultaneous Recording
Rotary Absorber
Zeiss Stereo Discover V12 Microscope